Measuring Your Openings for Plantation Shutters

Type 0
Inside Mount
Regardless of Sill or Trim
1. Louver Clearance. Make sure you have adequate depth in the opening for the louvers you would like. The table sets out the clearance depth measured from the front of the panel stiles to the window.
Louver Clearance Table
The purpose of this table is to help you determine if you have
adequate depth inside your opening for unobstructed louver rotation.
|
|
Louver Size
|
1-1/4"
|
1-7/8"
|
2-1/4"
(Faux Wood Only)
|
2-1/2"
|
3-1/4"
(Faux Wood Only)
|
3-1/2"
|
4-1/2"
|
5-1/2"
|
|
Depth from front of panel to window
|
1-1/8"
|
1-1/4"
|
1-5/8"
|
1-3/4"
|
2-1/8"
|
2-1/2"
|
2-3/4"
|
3-1/4"
|
2. Measuring. Measure the width & height in 3 places from inside the opening. Enter the smallest width and height on the order form.
3. Mounting. Which is right for you; a Direct Mount or an Indirect Mount for Opening Type 0?
A Direct Mount is primarily used when the window jamb is wood. The wood jamb provides a solid attachment point for the hinge. It is also used when the window dimensions are fairly consistent (within 3/16"). Moldings are supplied free of charge - (4) #10 Light stops.
An Indirect Mount is primarily used when the window jamb is drywall. It is also used when the window dimensions are inconsistent (in excess of 1/4" difference). Standard Moldings are supplied free of charge - (2) #15 Hang strips and ( 2) #11 Light stops.
|